Loading Supplies 3-15
Press the FEED button. The indicator light should
be GREEN.
Calibrate the supply if necessary. See
“Calibrating the Supply,” for more information.
Calibrating the Supply
Turn off the printer.
Press and hold the FEED button while turning on
the printer.
To calibrate the supply, release the FEED button
after the indicator light starts flashing ORANGE.
The printer calibrates the black mark or die cut
sensor, measures the label length, and prints the
test labels.
To calibrate the ribbon, release the FEED button
after the printer starts flashing RED. The printer
calibrates the ribbon sensor.
To resume normal printing, turn off the printer,
wait two seconds, then turn it back on again.